---+ n-XYTER - Read-out ASIC for High Resolution Time and Amplitude Measurements %TOC% ---++ Introduction <div style="padding:5px 5px; float:right"> <a padding: 1px 1px" href="%ATTACHURLPATH%/nXYTER-arch.png" title="click for larger image"> \ <img style="padding:5px 5px; background-color: #f0f0f0" src="%ATTACHURLPATH%/nXYTER-arch-small.png" \ alt="n-XYTER Architecture"/> </a> <br/> <a padding: 1px 1px" href="%ATTACHURLPATH%/nXYTER-token.png" title="click for larger image"> \ <img style="padding:5px 5px; background-color: #f0f0f0" src="%ATTACHURLPATH%/nXYTER-token-small.png" \ alt="n-XYTER Architecture"/> </a> <img src="%ATTACHURLPATH%/nXYTER-pict.png" alt="n-XYTER Pictures"/> </div> The n-XYTER ASIC was developed in context of the EU-FP6 Integrated Infrastructure Initiative [[http://neutron.neutron-eu.net/n_nmi3][NMI3]] in the Joint Research Activity [[http://jra1.neutron-eu.net/jra1/][DETNI]] as the common read-out solution for three different, solid converter based neutron counting area detectors. Because of the the statistical, non-triggerable nature of neutron data to be processed, the internal architecture of the chip is self triggered and data driven. It integrates 128 channels with low noise preamplifiers and shapers. Each channel has two different shapers with distinct time constants, one optimized for timing resolution, the other one optimized for energy (pulse height) resolution. A peak detector connected to the slower shaper allows for the application of a spectroscopic amplitude measurement. An internal time stamp generator provides the temporal reference that may be employed to identify time coincidences of signals on different detector channels and thus correlate their spatial point of origin. For testability and calibration purposes, a charge injector with adjustable pulse height was implemented. The bias settings and various other parameters can be controlled via a standard I2C-interface. ---++ Key Features * mixed signal chip * process: AMS 0.35 μm CMOS * 128 channels * 1 test channel with analogue diagnostic output * architecture for AC-coupling, employable for positive and negative signals * self triggered, data driven de-randomizing, sparcifying readout at 32 MHz * digital time stamp output * analogue peak hight output * maximum data loss at 32 MHz average input rate over 16 μs: 4% * analogue pile-up registry * programmable dead time * local threshold adjustment * Dynamic Range: 120000 e * Shaping time and noise performance: * 30 ns fast shaper at 30 pF input, 850 enc for positive signals, 1000 enc for negative signals * 130 ns slow shaper at 30 pF input, 600 enc * Timing resolution ~ 2-3 ns, time stamp resolution 1 ns ---++ Documentation * n-XYTER Reference Manual, describes in detail electrical specifications, operating conditions and port definitions of the readout chip n-XYTER 1.0. * [[%ATTACHURL%/nXYTER.pdf][Version 1.40 (Draft) of 25.05.2009]] (Improvements on strategies for finding Vcm settings and help for compensation of temp co.) * [[http:/cgi-bin/viewfile/Public/PublicNxyter?rev=1.4&filename=nXYTER.pdf][Version 1.30 (Draft) of 29.03.2009]] * [[http:/cgi-bin/viewfile/Public/PublicNxyter?rev=1.3&filename=nXYTER.pdf][Version 1.30 (Draft) of 29.07.2008]] * [[http:/cgi-bin/viewfile/Public/PublicNxyter?rev=1.2&filename=nXYTER.pdf][Version 1.30 (Draft) of 24.07.2008]] * [[http:/cgi-bin/viewfile/Public/PublicNxyter?rev=1.1&filename=nXYTER.pdf][Version 0.90 of 28.02.2008]] ---++ Papers and Presentations * C.J. Schmidt _et al._, [[http://indico.cern.ch/contributionDisplay.py?contribId=84&sessionId=11&confId=11994][Test results on the n-XYTER ASIC, a self triggered, sparcifying readout ASIC]], Topical Workshop on Electronics for Particle Physics 2007, [[http://www.particle.cz/conferences/twepp07/][TWEPP-07]], 3-7 September 2007, Prague * A.S. Brogna _et al._, [[http://dx.doi.org/10.1016/j.nima.2006.06.001][N-XYTER, a CMOS read-out ASIC for high resolution time and amplitude measurements on high rate multi-channel counting mode neutron detectors]], Nucl. Instrum. Methods A 568 (2006) 301308 -- Main.WalterFJMueller - 30 Apr 2008
Attachments
1
Attachments
1
Topic attachments
I
Attachment
Action
Size
Date
Who
Comment
pdf
nXYTER.pdf
manage
2913.1 K
25 May 2009 - 17:15
MarcusHoehl
nXYTER Reference Manual V1.4, 25.05.2009
Edit
|
Attach
|
P
rint version
|
H
istory
:
r16
|
r14
<
r13
<
r12
<
r11
|
B
acklinks
|
V
iew topic
|
Edit WikiText
|
More topic actions...
Topic revision: r13 - 26 May 2009,
WalterFJMueller
Public
CBM Homepage
Public Web
Public Web Home
Changes
Index
Search
Webs
Homepages
Main
MiniCBM
Public
Sandbox
System
Create
personal sidebar
Български
_jméno_jazyka
Dansk
Deutsch
English
Español
Suomi
Français
Italiano
日本語
한글
Nederlands
Norsk
Polski
Português
Português brasileiro
Русский
Svenska
简体中文
正體中文
Copyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding CBM Wiki?
Send feedback
Imprint (in German)
Privacy Policy (in German)